Skip to main content
. Author manuscript; available in PMC: 2011 Dec 1.
Published in final edited form as: Cytometry A. 2010 Dec;77(12):1103–1112. doi: 10.1002/cyto.a.20978

Table 1.

Number of training instances, sensitivity, specificity, accuracy, AUC, and standard deviation of AUC values for 10× cross-validation of the RBF-SVM classifier, computed for every classified serotype.

Classified serotype No. of training instances Sensitivity Specificity Accuracy AUC AUC sd
Salmonella Agona 76 0.9868 0.9972 0.9951 0.9997 0.000958
Salmonella Cholerasuis 49 0.8775 0.9843 0.9715 0.9950 0.008322
Salmonella Indiana 33 0.9697 1 0.9976 1 0
Salmonella Kentucky 41 0.8780 0.9872 0.9761 0.9793 0.046659
Salmonella Schottmuelleri 48 0.9167 0.9948 0.9855 0.9933 0.015494
Salmonella Tennessee 94 1 0.9881 0.9903 0.9994 0.001241
Salmonella Typhimurium (Copenhagen) 90 0.9444 0.9883 0.9785 0.9959 0.007536