Skip to main content
. Author manuscript; available in PMC: 2012 Dec 1.
Published in final edited form as: Liver Transpl. 2011 Dec;17(12):1427–1436. doi: 10.1002/lt.22419

Table 2.

Results of Numerical Simulation

Slice thickness / interval (mm) Difference (%)
assumption A: minimum assumption B: middle assumption C: maximum
10 −9.143 −0.391 9.570
5 −4.634 −0.098 4.736
2.5 −2.331 −0.024 2.356
1.25 −1.169 −0.006 1.175
0.625 −0.585 −0.002 0.587

Note. – Values show the differences of the volumes of a sphere 8 cm in radius in percent figures as follows: Differences (%) = [(calculated volume based on simulation) − (exact volume)] / (exact volume) × 100 (%) Exact volume of the sphere = (4/3) π × 83 = 2144.66 cm3.