Skip to main content
. 2011 Nov 17;2011:287186. doi: 10.1155/2011/287186

Table 1.

Nominal model parameters and sensitivity analysis. The sensitivity analysis is carried out by considering the nominal parameter values as the baseline (with the COC centrally located within the follicle) and calculating the change in the mean O2 concentration at the COC boundary (r C) for a 10% increase or decrease in each parameter from the baseline.

Parameter Value Reference +10% −10%
αG 0.3 (no units) [14, 15] −1.5% +1.4%
CP 0.128 (mol m−3) [14] +41% −41%
DA 2.5 × 10−9 (m2 s−1) [28] +25% −30%
DG 2.5 × 10−9 (m2 s−1) [28] +3.1% −3.7%
hP 0.1 (m s−1) Variable (see text) See discussion See discussion
qG 0.0363 (mol m−3 s−1) [14] −3.1% +3.1%
q COC 1.62 × 10−6 (mol m−2 s−1) From [44], units converted using r C −28% +28%
rF 1 × 10−3 (m) See text +1.9% −4.5%
rC 160 × 10−6 (m) [45] +30% −37%
vG 1.14 × 10−15 (m3) [15] −6.9% +6.2%
a 43.1 × 106 [15] −6.9% +6.2%
b 281.6 [15] +5.6% −7.6%
c −387.3 [15] −5.4% +4.6%