Table 1.
Parameter values used to generate random numbers in computer simulations of a force response due to myosin crossbridges subjected to sinusoidal length perturbations, and estimated parameter values from that force response fit to (15). For all simulations , N = 20,000 and kstiff = 1 pN/nm. Est[] = estimated value of bracketed parameter, () indicates the ±95% confidence intervals for estimated value. The correlation between actual and estimated values resulted in a correlation coefficient greater than 0.997 for each parameter.
Sim number | p | β (ms) | (ms) | ξ (pN/nm) | Est[p] | Est[β] (ms) | Est[] (ms) | Est[ξ] (pN/nm) |
---|---|---|---|---|---|---|---|---|
(1) | 1 | 24 | 24 | 4000 | 0.91 (0.01) | 25.13 (0.06) | 22.89 | 4005.0 (0.5) |
(2) | 2 | 12 | 24 | 4000 | 2.01 (0.01) | 11.98 (0.03) | 24.09 | 4019.8 (0.4) |
(3) | 3 | 8 | 24 | 4000 | 3.22 (0.01) | 7.48 (0.02) | 24.08 | 3981.2 (0.4) |
(4) | 6 | 4 | 24 | 4000 | 6.11 (0.02) | 3.89 (0.01) | 23.79 | 3986.4 (0.4) |
(5) | 8 | 3 | 24 | 4000 | 8.70 (0.03) | 2.75 (0.01) | 23.95 | 3997.4 (0.4) |
(6) | 4 | 24 | 96 | 10000 | 3.99 (0.01) | 24.03 (0.03) | 95.88 | 10007.0 (0.3) |
(7) | 8 | 12 | 96 | 10000 | 6.83 (0.01) | 13.93 (0.02) | 95.12 | 10003.8 (0.3) |
(8) | 12 | 8 | 96 | 10000 | 12.00 (0.02) | 7.98 (0.01) | 95.71 | 10012.8 (0.3) |
(9) | 16 | 6 | 96 | 10000 | 16.04 (0.03) | 6.05 (0.01) | 97.03 | 10022.6 (0.3) |
(10) | 24 | 4 | 96 | 10000 | 24.10 (0.06) | 3.99 (0.01) | 96.07 | 10017.2 (0.3) |
(11) | 48 | 2 | 96 | 10000 | 49.61 (0.15) | 1.92 (0.01) | 95.13 | 10004.0 (0.3) |
Note: .