Table 6.

The optimal solutions to the third stage (10a)(10d) where readers R7 and R9 are inactivated and d = 15 m.

Frame size Reader utilization Energy consumption Time slot Scheduled reader (channel number, power(mW))
3 12 0.386 W 1st R1(3, 30), R4(4, 27), R6(1, 31), R12(2, 33)
2nd R5(3, 31), R8(2, 34), R10(1, 31), R12(4, 27)
3rd R2(4, 29), R3(2, 41), R11(1, 35), R12(3, 37)