Table 1.
Parameter | Value |
---|---|
Sensing range | 40 cm to 300 cm |
Target dimensions for max. meas. dist. | 5 cm × 5 cm |
Response time | 50 ms to 200 ms |
Accuracy | ±1.5% |
Resolution | 1 mm |
Beam angle | Approx. 5° |
Sensor output | 0 VDC a 10 VDC |
Ultrasound frequency | 120 kHz |
Weight | approx. 150 g |
Ambient temperature (compensation) | −25 °C to +70 °C |
Operating voltage | 20 VDC to 30 VDC |
Vibrating stress | 11 to 55 Hz, 1 mm amplitude |
Shock stress | 30 g, 18 ms |
Degree of protection | IP 65 |