Skip to main content
. 2011;19(3):210–215.

Table 3.

Mean (±SD) pharmacokinetic parameters of Pd-Ia after intravenous administration

Parameters Control Liver Cirrhosis
Initial body weight (g) 190±13.4 189±12.5
Final body weight (g) 376±21.6 269±18.6**
AUC0-8 (min·µg·ml−1) 68.4±13.9 111.8±29.7**
t1/2 (min) 59.2±9.0 99.4±10.8**
CL (ml·min−1) 15.5±2.3 8.3±1.8**
Vz(1) 1.3±0.26 1.2±0.35
8 h Bile (% of dose) 0.092±0.0033 0.126±0.0060**
Ae0–24 h (% of dose) 0.114±0.0166 0.156±0.0252**
GI24 h (% of dose) BDL BDL

AUC0-8: area under the analyte concentrations versus time curve from time 0 to infinity; t 1/2: terminal half-life; CL: total body clearance;

Vz: terminal volume of distribution; Ae0–24 h: urine samples at 24 hrs; GI24 h: gastrointestinal tract samples at 24 hrs

BDL: below the detection limit.

**P<0.01, significant difference compared to control.