Skip to main content
. Author manuscript; available in PMC: 2012 Sep 1.
Published in final edited form as: Bone. 2011 May 27;49(3):439–446. doi: 10.1016/j.bone.2011.05.017

Table 1.

Peak applied compressive loads and resulting peak mid-diaphyseal strains on the medial tibia and peak proximal metaphyseal cancellous tissue strains.

Experimental
Group
Applied Load
(N)
Mid-diaphyseal
Strains (με)b
Cancellous Tissue
Strains (με)c
Growinga −11.5±0.3 +1200 −2437±155
Load-Matched −11.3±0.5 +2200 −2130±273
Strain-Matched −5.9±0.5 +1200 −1178±109
a

10wk female mice undergoing 2wks in vivo loading [24]

b

Determined by in vivo strain gauging at the medial mid-diaphysis

c

Determined by finite element modeling of the proximal metaphysis in control limbs.

Data represented as mean ± SD where appropriate.