Skip to main content
. Author manuscript; available in PMC: 2012 Dec 1.
Published in final edited form as: J AAPOS. 2011 Dec;15(6):573–578. doi: 10.1016/j.jaapos.2011.06.011

Table 2.

Intraphysician reliability for ROP diagnosis by the expert reference standard and five pediatric ophthalmology fellowsa

Physician Mild or worse ROP Type 2 or worse ROP Treatment-requiring ROP
Reference standard 0.904 (0.066) 1.000 (−) 0.730 (0.145)
Fellow 1 0.8835 (0.080) 0.727 (0.113) 1.000 (−)
Fellow 2 1.000 (−) 0.659 (0.128) 0.828 (0.119)
Fellow 3 0.936 (0.063) 0.762 (0.131) 0.742 (0.142)
Fellow 4 0.843 (0.087) 1.000 (−) 1.000 (−)
Fellow 5 0.845 (0.086) 0.750 (0.119) 0.857 (0.099)
a

Results are displayed as kappa statistic (standard error) for ability to detect mild or worse ROP, type-2 or worse ROP, and treatment-requiring ROP.