Skip to main content
. 2011 Nov 30;11(12):11357–11371. doi: 10.3390/s111211357

Table 1.

EERs (%) by varying N and S for LLBP based on a sub-dataset of finger vein images (N: length of the line, S: size of the filtering mask.)

S
11 13 15 17 19
N

17 3.33 2.11 2.11 2.78 2.67
19 3.22 2.11 2.11 2.56 2.56
21 3.22 2.11 1.89 2.56 2.56
23 3.22 2.11 1.89 2.56 2.33
25 3.22 2.00 1.89 2.44 2.33