Skip to main content
. 2011 Sep 1;13(1):29–37. doi: 10.1007/s10194-011-0379-4

Table 2.

Measures of excitability to transcranial magnetic stimulation in control subjects

CS MT Pre-EL MT Post-EL MT Pre-LD MT Post-LD SICI Pre-EL SICI Post-EL SICI Pre-LD SICI Post-LD N Pre-EL N Pre-EL N Pre-LD N Post-LD
1 33 32 29 31 40.1 23.8 55.1 44.5 44 26 19 17
2 36 34 33 36 54.9 28.0 51.1 36.2 17 41 24 16
3 56 51 58 58 23.8 7.5 15.0 5.3 22 19 13 13
4 57 58 56 56 67.1 38.0 14.9 36.5 20 43 50 18
5 39 40 41 43 145.9 113.9 86.5 86.6 24 18 14 20
6 34 34 31 35 38.3 28.3 63.9 52.7 21 21 21 51
7 45 42 51 43 106.8 46.55 194.2 120.8 29 14 16 17
8 30 30 30 28 69.5 65.8 47.2 40.5 20 17 20 25
9 31 31 31 31 33.8 32.9 41.0 46.1 32 31 17 17
Mean 40.1 39.1 40.0 40.1 64.5 42.8 63.2 52.1 25.4 25.6 21.6 21.6
SE 3.2 3.1 3.7 3.4 12.4 9.8 17.0 10.4 2.6 3.3 3.5 3.6

Motor thresholds (MT, % of stimulator’s output), short-interval intracortical inhibition (SICI, %), and number of stimuli (N) in determination of MT in control subjects pre- and post-standard room light exposure (EL) and pre- and post-light deprivation (LD)

SE standard error