Skip to main content
. Author manuscript; available in PMC: 2012 Nov 1.
Published in final edited form as: Exp Brain Res. 2011 Sep 28;215(2):123–134. doi: 10.1007/s00221-011-2880-z

Table 2. Regression Models Associating Sit-to-Stand Modifications With CNV Amplitudes.

Condition
Difference
Electrode Sit-to-Stand
Modification
Coefficient of
Determination
Change in F
Statistic
Significance
of F Change
NoPain1 Minus
Pain
Cz
Maximum Vertical
Force Under Feet
0.30 5.08 P = 0.044
C4
Maximum Vertical
Force Under Feet
0.49 11.50 P = 0.005
Initial Erector
Spinae Activity
0.72 8.85 P = 0.013
Time of Peak
Ankle Flexion
0.85 8.36 P = 0.016
Movement
Time
0.91 6.15 P = 0.035
Peak Hip
Flexion
0.95 5.43 P = 0.048
NoPain1 Minus
NoPain2
Cz
Time of Peak
Hip Extension
0.48 10.97 P = 0.006
C4
Peak Ankle
Flexion
0.52 12.81 P = 0.004