Parameters Relevant for the Calculation of the Pressure Drop Δp in Equation 1/(A1)

de (μm) do (μm) Rlumen (Pa sm−3) NRlumen (Pa sm−3) Rplate (Pa s/m3) (N−1) × Rplate (Pa sm−3) Rplug (Pa s/m3) MRplug (Pa s/m3) R (Pa s/m3) Q (m3/s) Δp (MPa)
3.0 1.0(*) 7.8 × 1016 9.8 × 1019 1.5 × 1017 1.9 × 1020 3.5 × 1017 4.4 × 1019 3.3 × 1020 7.1 × 10−16 0.23
3.0 0.50 7.8 × 1016 9.8 × 1019 1.5 × 1017 1.9 × 1020 5.2 × 1018 6.5 × 1020 9.4 × 1020 7.1 × 10−16 0.66
3.0 0.23 7.8 × 1016 9.8 × 1019 1.5 × 1017 1.9 × 1020 7.5 × 1019 9.4 × 1021 9.7 × 1021 7.1 × 10−16 6.8
3.0 (†) 7.8 × 1016 9.8 × 1019 1.5 × 1017 1.9 × 1020 (†) (†) 2.9 × 1020 7.1 × 10−16 0.20
2.4 1.0(*) 1.9 × 1017 2.4 × 1020 1.5 × 1017 1.9 × 1020 3.5 × 1017 4.4 × 1019 4.7 × 1020 4.5 × 10−16 0.21
2.4 0.50 1.9 × 1017 2.4 × 1020 1.5 × 1017 1.9 × 1020 5.2 × 1018 6.5 × 1020 1.1 × 1021 4.5 × 10−16 0.49
2.4 0.23 1.9 × 1017 2.4 × 1020 1.5 × 1017 1.9 × 1020 7.5 × 1019 9.4 × 1021 9.8 × 1021 4.5 × 10−16 4.4
2.4 (†) 1.9 × 1017 2.4 × 1020 1.5 × 1017 1.9 × 1020 (†) (†) 4.3 × 1020 4.5 × 10−16 0.19

Calculated values of the lumen resistance Rlumen, plate resistance Rplate, agglomeration resistance Rplug, and total resistance R determined from Equations (A3), (A4), (A5), and (A2) (see Supplemental Appendix 1 and Supplemental References 1 online). The results are given for two values of the effective sieve tube diameter de and three values of the agglomeration opening diameter do. de = 3.0 μm corresponds to a completely empty sieve tube, and de = 2.4 μm corresponds to a sieve tube with only 65% of the area open to flow. Results marked with an asterisk indicate the measured value of do = 1 μm. Results marked with (†) indicate the case where no At SEOR1 agglomerations are present.