Skip to main content
. Author manuscript; available in PMC: 2012 May 1.
Published in final edited form as: Exp Brain Res. 2011 Mar 6;210(3-4):623–640. doi: 10.1007/s00221-011-2599-x

Table 2.

Electrical stimulation parameters for each of 26 cases tested and modeled.

Animal Target Ampulla Electrode Arrangement Stimulus Current (μA) Phase Duration (μs) Modulation Frequency (Hz) Modulation Limits (pulse/s)
CH050506A LA Monopolar 140 200 0.5 40 – 300
LH Bipolar 290 230 2 40 – 300
LP Monopolar 100 200 2 40 – 300
CH050506B LA Bipolar 280 200 2 30 – 300
Monopolar 50, 100, 120, 140, 210 200 2 30 – 300
LH Bipolar 230 200 2 30 – 300
Monopolar 75, 100, 110, 120, 160, 175 200 2 30 – 300
LP Monopolar 20, 50, 100, 120, 150, 200 200 2 30 – 300
CH071105 LA Monopolar 250 200 2 50 – 270
LH Monopolar 250 200 2 50 – 270
LP Monopolar 250 200 2 50 – 270
CH072106 LP Monopolar 260 100 2 20 – 300

LA, LH, LP: Left anterior, horizontal and posterior semicircular canals, respectively.