Skip to main content
. 2010 Dec 31;11(1):362–383. doi: 10.3390/s110100362

Table 1.

Frequency of observed versus predicted activity and misclassification rates obtained in the inference of animal activity, classified as GRT and GLST, by discriminant analysis of results obtained from Lotek GPS collars only, IceRobotics IceTag pedometers only, and both devices together. Elements on the upper-left to lower-right diagonal (bold) are correctly classified observations. Ideally, all observations should fall on this diagonal. G = Graze, R = Rest, T = Travel, L = Lie, S = Stand.

Classi-fication Device Observed Activity Predicted Activity
Misclassification Rate (%)
G R S T
GRT GPS collar G 350 136 3 28
R 85 809 4 10
T 7 1 80 9
All 16
Pedometer G 477 3 9 2
R 359 539 0 40
T 6 0 82 7
All 26
Both G 437 46 6 11
R 100 798 0 11
T 5 0 83 6
All 11
GLST GPS collar G 330 46 110 3 33
L 20 356 130 2 30
S 48 154 174 2 54
T 7 0 1 80 9
All 36
Pedometer G 270 0 210 9 45
L 1 502 5 0 1
S 60 13 305 0 19
T 6 0 0 82 7
All 21
Both G 363 0 120 6 26
L 1 502 5 0 1
S 48 13 317 0 16
T 5 0 0 83 6
All 14