Skip to main content
. 2011 Jul 1;69(3):176–183. doi: 10.1136/oem.2011.064758

Table 5.

ORs (95% CIs) of hearing loss and noise notch by noise exposure levels at longest job

Variables Model A* Model B Model C
A. ORs of hearing loss Hearing loss no./participants no.
O*NET noise (unit score)§ 1.74 (1.35 to 2.26) 1.68 (1.30 to 2.18) 1.65 (1.28 to 2.13)
O*NET noise quintile
 Quintile 1 (1.795–2.588) 65/695 1 (Reference) 1 (Reference) 1 (Reference)
 Quintile 2 (2.653–2.729) 76/830 1.04 (0.62 to 1.72) 1.01 (0.60 to 1.69) 0.99 (0.59 to 1.65)
 Quintile 3 (2.737–2.868) 67/731 1.14 (0.64 to 2.03) 1.10 (0.62 to 1.96) 1.09 (0.61 to 1.95)
 Quintile 4 (3.121–3.631) 112/805 1.61 (0.96 to 2.70) 1.50 (0.89 to 2.52) 1.43 (0.87 to 2.36)
 Quintile 5 (3.667–4.368) 136/767 2.30 (1.32 to 4.01) 2.14 (1.22 to 3.75) 2.07 (1.18 to 3.63)
p Trend 0.001 0.0019 0.0026
B. ORs of noise notch Noise notch no./participants no.
O*NET noise (unit score)§ 1.45 (1.20 to 1.76) 1.43 (1.18 to 1.73) 1.41 (1.17 to 1.70)
O*NET noise quintile
 Quintile 1 (1.795–2.588) 101/695 1 (Reference) 1 (Reference) 1 (Reference)
 Quintile 2 (2.653–2.729) 119/830 0.98 (0.67 to 1.42) 0.97 (0.67 to 1.42) 0.96 (0.66 to 1.40)
 Quintile 3 (2.737–2.868) 77/731 0.80 (0.58 to 1.11) 0.80 (0.58 to 1.10) 0.79 (0.57 to 1.09)
 Quintile 4 (3.121–3.631) 168/805 1.40 (1.05 to 1.87) 1.37 (1.02 to 1.84) 1.35 (1.00 to 1.81)
 Quintile 5 (3.667–4.368) 190/767 1.60 (1.16 to 2.20) 1.55 (1.12 to 2.14) 1.51 (1.09 to 2.09)
p Trend 0.0016 0.0032 0.0045
*

Model A was adjusted for age, age2, sex and race/ethnicity.

Model B: model A+further adjusted for body mass index, ototoxic medication, cumulative cigarette pack-years, current diagnosis of hypertension and current diagnosis of diabetes.

Model C: model B+further adjusted for recreation noise and firearm noise.

§

Per cent change in hearing thresholds for one-unit score increase.

O*NET, Occupational Information Network.