—[Section 7.1] Risk of Bleeding With Enoxaparin According to the Calculated Creatinine Clearance

Bleeding Rate CalCrCl ≤ 30, n/N (%) Bleeding Rate CalCrCl > 30, n/N (%) OR (95% CI)
Studies where dose was unadjusted for CalCrCl 17/206 (8.3) 96/4,081 (2.4) 3.88 (1.78-8.45)
Studies where dose was adjusted for CalCrCl 1/106 (0.9) 5/265 (1.9) 0.58 (0.09-3.78)

CalCrCl = calculated creatinine clearance.