Skip to main content
. 2012 Feb 14;3:17. doi: 10.3389/fphys.2012.00017

Table 2.

Results of the hemodynamic measurements at the beginning (pre) and at the end of the experiment (post).

L-IV L-IC Control
CO (l/min)
   Pre 4.07 ± 0.70 3.38 ± 0.37 3.23 ± 0.37
   Post 2.28 ± 0.61* 1.57 ± 0.23* 2.00 ± 0.35*
MAP (mmHg)
   Pre 61.88 ± 8.71 65.88 ± 14.5 61.00 ± 8.11
   Post 83.5 ± 17.71* 85.38 ± 21.82 80.25 ± 17.90
HR (/min)
   Pre 105.13 ± 16.39 111 ± 9.99 106.13 ± 20.1
   Post 105.5 ± 23.13 108.63 ± 12.97 105.86 ± 12.9
CVP (mmHg)
   Pre 3.63 ± 3.70 3.13 ± 0.99 2.88 ± 0.83
   Post 3.13 ± 3.04 4.25 ± 2.05 4.38 ± 1.30
PCWP (mmHg)
   Pre 3.75 ± 3.77 4.25 ± 1.67 4.38 ± 2.2
   Post 3.13 ± 3.18 5.5 ± 4.44 3.75 ± 1.16
SVR
   Pre 14.51 ± 1.48 18.67 ± 4.11 18.28 ± 3.88
   Post 38.63 ± 9.90* 51.42 ± 9.38* 38.95 ± 11.2*
Calculated SW
Pre 2.49 ± 0.92 2.02 ± 0.59 1.93 ± 0.52
Post 1.86 ± 0.93 1.25 ± 0.43 1.54 ± 0.49

Data presented as mean ± SEM. L-IV, levosimendan infusion-group, L-IC, intracoronary levosimendan-group. CO, cardiac out-put; MAP, mean arterial pressure; HR, heart rate; CVP, central venous pressure; PCWP, pulmonary capillary wedge pressure; SVR, systemic vascular resistance, Calculated SW = left ventricle stroke work = (CO/HR) × MAP. *p < 0.05 pre vs. post, p < 0.05 between groups (values in bold).