Table 2. Lung Function Values: Before (Pre) and After (Post) PEP and HFCC Treatments .
Device | FEV1 |
FEF25-75 (%) |
FVC (%) |
SpO2 (%) |
||||
(% predicted) | ||||||||
pre | post | pre | post | pre | post | pre | post | |
HFCC | 67 ± 17 | 66 ± 17 | 34 ± 21 | 33 ± 21 | 88 ± 17 | 87 ± 16 | 97 ± 1.6 | 97 ± 1.2 |
PEP | 67 ± 16 | 67 ± 16 | 34 ± 20 | 34 ± 19 | 88 ± 15 | 87 ± 15 | 98 ± 1.0 | 97 ± 1.2* |
FEV1: forced expiratory volume in 1 second; FEF25-75: forced expiratory flow 25 - 75%; FVC, forced vital capacity. *P < 0.001. No statistically significant difference was found in spirometric values before and after both treatments. A statistically significant decrease in SpO2 values was found after PEP treatment.