Table 2. Sequence parameters typically used at the author’s institutions.

Typical sequence parameters used. Settings and sequence names are vendor specific and can vary.

T2w coronal 3D T2wMRCP Axial T2w Dynamic phases
& standard delayed phases
Hepatobiliary phase
high-resolution
Sequence SSFSE / HASTE / single-
shot TSE / FSE
RARE-based
3D fat-sat
FSE fat sat GRE or volume interpolated 3D SPGR
(VIBE / LAVA / THRIVE / TIGRE) with
spectral-spatial fat-sat
GRE 3D SPGR
spectral-spatial fat-sat
Orientation coronal coronal axial axial axial
Purpose check for cholestasis, if
present, perform MRCP
cholangiogram T2w images dynamic phase imaging
dur: fluoroscopic trigger
portal venous: ~50sec after arterial peak
venous: ~2min after arterial peak
near-isotropic scan to visualize biliary
system
at contrast agent-specific delay

TR/TE 1000/90 3750/590
(120)
15000/94
(ETL 16)
4/1.9 5.4/2.1
FOVx/FOVy 512 × 512 512 × 512 512 × 512
(75%)
512 × 512
(75%)
400 × 320
Acq Matrix 352 × 256 288 × 288 324 × 224 256 × 192 228 × 224
FA 90 90 90 12-15 variable
40-45 gadoxetic acid
25-30 gadobenate dimeglumine
Number of signal averages 0.53 1 2 1 1
Slice thickness 6 1.4 5 5 2
No. of slices
(requirements)
24
a) as much as possible
in a 20-24s breath hold
b) cover the entire liver
112
a) anatomically
adapted to cover the
biliary tree
58
a) anatomically adapted
to cover the entire liver
16
a) as much as possible in a 20-24s breath
hold
b) cover the entire liver
192
a) as much as possible in a 20-24s
breath hold (alternative: navigator-
gating)
b) cover the entire liver
Interslice gap none 0.7 15% none none
Receiver bandwidth ±50kHz ±50kHz ±50kHz ±62.5kHz ±62.5kHz
Applied coil 8ch phased array 8ch phased array 8ch phased array 8ch phased array 32ch body phased array
True resolution [mm3] 1.5 × 2.0 × 6.0 1.8 × 1.8 × 1.4 1.6 × 2.3 × 5.0 2.0 × 2.7 × 5.0 1.39 × 1.8 × 2.0
Interpolated res. [mm3] 1.0 × 1.4 × 2.5 0.8 × 0.8 × 1.0
Breathing breath hold respiratory triggered respiratory triggered breath hold breath hold
Acceleration techniques Data-driven or image-
based parallel imaging
Data-driven or image-based parallel
imaging
Data-driven or image-based parallel