Ref (type) | Population | Outcome, Interventions | Results and statistical analysis | Effect size | Favours |
Patient satisfaction | |||||
Systematic review |
321 women Data from 1 RCT |
Patient satisfaction 12 months
148/166 (89%) with laser ablation 140/155 (90%) with transcervical endometrial resection |
OR 0.88 95% CI 0.43 to 1.81 P = 0.73 |
Not significant | |
Systematic review |
91 women Data from 1 RCT |
Patient satisfaction 12 months
45/47 (96%) with vaporising electrode ablation 41/44 (93%) with transcervical endometrial resection |
OR 1.65 95% CI 0.26 to 10.35 P = 0.60 |
Not significant | |
RCT |
50 women |
Satisfied or very satisfied 2 years
64% with 5-mm rollerball with unmodulated cutting current 68% with 5-mm rollerball with modulated coagulating current Absolute numbers not reported |
P = 0.46 |
Not significant |