Table I.

Patient, implant and seizure-onset information.

Patient Hemisphere Sex Age Electrode Arrays Seizure Focus
P1 Left Male 21 Four 2×8
One 1×8
One 8×8
Left Anterior Temporal
P2 Left Male 22 One 1×8
Four 1×4
One 8×8
Left Cingulate Cortex
P3 Left Male 29 One 1×8
Four 1×4
Left Anterior Temporal and Left Parietal
P4 Left Female 23 One 8×8
Five 1×4
Anterior Middle Frontal
P5 Left Male 20 One 8×8
Four 1×4
Posterior Superior Temporal and Middle Frontal