Table 2.
0.2 Hz | 0.3 Hz | 1Hz | 2 Hz | 3Hz | |
---|---|---|---|---|---|
O2 (less conservative) | |||||
S1 | |||||
Tσ, °/s | 0.42 (±0.043) | 0.47 (±0.050) | 0.56 (±0.049) | ||
Bias, °/s | 0.262 | 0.120 | 0.038 | ||
S2 | |||||
Tσ, °/s | 0.23 (±0.032) | 0.29 (±0.032) | 0.32 (±0.041) | 0.45 (±0.045) | 0.41 (±0.043) |
Bias, °/s | −0.229 | −0.222 | −0.455 | −0.379 | −0.444 |
S3 | |||||
Tσ, °/s | 0.23 (±0.0329) | 0.22 (±0.035) | 0.23 (±0.032) | 0.49 (±0.051) | 0.59 (±0.059) |
Bias, °/s | 0.109 | 0.156 | 0.157 | 0.215 | 0.436 |
O1 (conservative) | |||||
S1 | |||||
Tσ, °/s | 0.59 (±0.070) | 0.61 (±0.030) | 0.76 (±0.082) | ||
Bias, °/s | 0.148 | 0.056 | −0.198 | ||
S2 | |||||
Tσ, °/s | 0.34 (±0.042) | 0.35 (±0.042) | 0.62 (±0.066) | 0.60 (±0.060) | |
Bias, °/s | −0.250 | −0.650 | −0.907 | −0.945 | |
S3 | |||||
Tσ, °/s | 0.33 (±0.038) | 0.68 (±0.720) | 0.69 (±0.068) | ||
Bias, °/s | 0.144 | 0.120 | 0.353 |
Fitted vestibuloocular reflex (VOR) thresholds (Tσ) (±SD in parentheses) as well as fitted bias values are shown for different operators (O1, O2), subjects (S1, S2, S3), and frequencies. Empty cells indicate conditions with too few trials (<200 accepted trials) for analysis.