Skip to main content
. 2011 Nov 9;107(3):973–983. doi: 10.1152/jn.00451.2011

Table 2.

Fitted VOR thresholds and fitted bias values for different operators, subjects, and frequencies

0.2 Hz 0.3 Hz 1Hz 2 Hz 3Hz
O2 (less conservative)
    S1
        Tσ, °/s 0.42 (±0.043) 0.47 (±0.050) 0.56 (±0.049)
        Bias, °/s 0.262 0.120 0.038
    S2
        Tσ, °/s 0.23 (±0.032) 0.29 (±0.032) 0.32 (±0.041) 0.45 (±0.045) 0.41 (±0.043)
        Bias, °/s −0.229 −0.222 −0.455 −0.379 −0.444
    S3
        Tσ, °/s 0.23 (±0.0329) 0.22 (±0.035) 0.23 (±0.032) 0.49 (±0.051) 0.59 (±0.059)
        Bias, °/s 0.109 0.156 0.157 0.215 0.436
O1 (conservative)
    S1
        Tσ, °/s 0.59 (±0.070) 0.61 (±0.030) 0.76 (±0.082)
        Bias, °/s 0.148 0.056 −0.198
    S2
        Tσ, °/s 0.34 (±0.042) 0.35 (±0.042) 0.62 (±0.066) 0.60 (±0.060)
        Bias, °/s −0.250 −0.650 −0.907 −0.945
    S3
        Tσ, °/s 0.33 (±0.038) 0.68 (±0.720) 0.69 (±0.068)
        Bias, °/s 0.144 0.120 0.353

Fitted vestibuloocular reflex (VOR) thresholds (Tσ) (±SD in parentheses) as well as fitted bias values are shown for different operators (O1, O2), subjects (S1, S2, S3), and frequencies. Empty cells indicate conditions with too few trials (<200 accepted trials) for analysis.