Table 4.

Experimental and simulated g-factors for the sixteen-channel array at 7T(left) and the simulated g-factors at 3T (right).

7T 3T
Anterior-Posterior
Reduction In vivo Model Model
1 2 1 2 1 2
Left-Right 1 mean 1.00 1.03 1.00 1.01 1.00 1.00
max 1.00 1.23 1.00 1.05 1.00 1.05

2 mean 1.01 1.05 1.01 1.02 1.03 1.04
max 1.10 1.30 1.06 1.09 1.17 1.17

3 mean 1.03 1.09 1.05 1.07 1.14 1.15
max 1.14 1.40 1.32 1.35 1.40 1.43

4 mean 1.11 1.21 1.10 1.12 1.25 1.29
max 1.36 1.65 1.35 1.39 1.71 1.81

5 mean 1.19 1.38 1.16 1.19 1.41 1.50
max 1.63 2.10 1.39 1.53 2.00 2.28

6 mean 1.27 1.60 1.33 1.27 1.68 1.87
max 1.84 2.73 1.59 2.02 2.43 3.10

7 mean 1.38 1.98 1.31 1.41 2.16 2.55
max 2.13 3.98 1.59 2.34 3.38 4.97

8 mean 1.58 3.17 1.52 1.72 2.98 3.93
max 2.78 >10 2.54 3.44 5.99 >10