Skip to main content
. Author manuscript; available in PMC: 2013 Jan 1.
Published in final edited form as: Sens Actuators A Phys. 2012 Jan;173(1):254–266. doi: 10.1016/j.sna.2011.09.009

Table 4.

Accuracies of the system at different orientations of the instrument when the neural network trained with the data obtained at 30° of orientation angles is used(The accuracy of the system at 30° is 99.67%). Reduction in accuracy is obtained by subtracting a particular accuracy from the accuracy at 30°.

β (°) α (°) Accuracy Reduction in accuracy (%)
10 10 99.36 0.31
15 15 99.64 0.03
20 20 99.56 0.11
30 30 99.66 0.01
40 40 99.46 0.21
45 45 99.55 0.12
50 50 99.65 0.02