Table 4.
Accuracies of the system at different orientations of the instrument when the neural network trained with the data obtained at 30° of orientation angles is used(The accuracy of the system at 30° is 99.67%). Reduction in accuracy is obtained by subtracting a particular accuracy from the accuracy at 30°.
β (°) | α (°) | Accuracy | Reduction in accuracy (%) |
---|---|---|---|
10 | 10 | 99.36 | 0.31 |
15 | 15 | 99.64 | 0.03 |
20 | 20 | 99.56 | 0.11 |
30 | 30 | 99.66 | 0.01 |
40 | 40 | 99.46 | 0.21 |
45 | 45 | 99.55 | 0.12 |
50 | 50 | 99.65 | 0.02 |