Table 1.
Instrument algorithm RNFL thickness measures for quadrant and clock hours for Cirrus and Spectralis SD-OCT. Along with the paired t-test statistic, the intraclass correlation coefficient (ICC) with 95% confidence intervals provides a measure of agreement for the two segmentation algorithms.
Cirrus | Spectralis | 95% Confidence | Paired t-test |
|||||
---|---|---|---|---|---|---|---|---|
Mean (µm) |
Std Dev | Mean (µm) |
Std Dev | ICC | Lower | Upper | ||
Global | 91.17 | 8.42 | 97.92 | 7.94 | 0.623 | −0.074 | 0.864 | <0.001 |
Temporal | 63.71 | 12.96 | 72.79 | 12.71 | 0.765 | −0.054 | 0.938 | <0.001 |
Superior | 115.03 | 14.94 | 118.52 | 12.98 | 0.734 | 0.552 | 0.847 | 0.022 |
Nasal | 65.89 | 10.06 | 74.56 | 15.88 | 0.559 | 0.119 | 0.780 | <0.001 |
Inferior | 120.08 | 16.39 | 125.21 | 15.21 | 0.764 | 0.544 | 0.876 | 0.001 |
Sector 1 | 49.57 | 8.70 | 58.81 | 10.87 | 0.631 | −0.071 | 0.887 | <0.001 |
Sector 2 | 77.15 | 19.18 | 85.73 | 17.53 | 0.853 | 0.068 | 0.957 | <0.001 |
Sector 3 | 125.78 | 21.95 | 134.40 | 23.92 | 0.780 | 0.491 | 0.895 | <0.001 |
Sector 4 | 114.12 | 24.88 | 112.97 | 22.18 | 0.797 | 0.658 | 0.883 | 0.613 |
Sector 5 | 105.17 | 16.77 | 108.18 | 18.31 | 0.794 | 0.653 | 0.882 | 0.075 |
Sector 6 | 80.23 | 17.45 | 90.59 | 23.26 | 0.743 | 0.256 | 0.893 | <0.001 |
Sector 7 | 55.31 | 9.79 | 62.95 | 15.50 | 0.414 | 0.110 | 0.640 | <0.001 |
Sector 8 | 62.12 | 10.60 | 70.13 | 16.12 | 0.571 | 0.182 | 0.776 | <0.001 |
Sector 9 | 95.75 | 18.21 | 99.21 | 18.00 | 0.701 | 0.517 | 0.824 | 0.100 |
Sector 10 | 134.94 | 26.79 | 137.62 | 27.59 | 0.801 | 0.666 | 0.885 | 0.301 |
Sector 11 | 129.53 | 26.72 | 138.45 | 25.62 | 0.885 | 0.465 | 0.959 | <0.001 |
Sector 12 | 64.40 | 15.79 | 73.37 | 15.84 | 0.759 | 0.080 | 0.915 | <0.001 |