Skip to main content
. 2012 Feb 28;8(4):430–441. doi: 10.7150/ijbs.3632

Table 1.

Comparison of LV chamber dimension and fraction shortening (FS) in sham-operated (Sham), myocardial infarction-induced (MI), sham-operated and treated with H2S (Sham+H2S), and myocardial infarction-induced and treated with H2S (MI+H2S) mice.

Experimental groups Sham Sham+H2S MI MI+ H2S
FS,% 64±0.4 65±0.8 28±0.4* 47±0.3*#
LVDd, mm 2.17±0.5 2.16±0.3 3.2±0.5* 2.85±0.5*#
LVDs, mm 0.87±0.2 0.98±0.5 2.15±0.4* 1.6±0.9*#

Presented results are calculated from the following equation [(LVDd−LVDs)/LVDd] ×100%.

* P < 0.05 vs. Sham and Sham+H2S, # P<0.05 vs. MI; n=9 for all groups.