Skip to main content
. 2012 Feb 6;33(6):724–733. doi: 10.1093/eurheartj/ehs016

Table 1.

Haemodynamic variables and loop areas in experimental study

  LBBB group
Ischaemia group
Baseline (n = 6) LBBB (n = 6) Baseline (n = 6) Ischaemia (n = 6)
Haemodynamic variables and ECG
 Heart rate (b.p.m.) 121 ± 17 122 ± 13 107 ± 16 134 ± 9*
 QRS width (ms) 68 ± 5 116 ± 7* 69 ± 9 67 ± 8
 LV dP/dtmax (mmHg/s) 1284 ± 198 1098 ± 189 1794 ± 337 1737 ± 102
 LV EDP (mmHg) 10 ± 3 10 ± 4 8 ± 1 10 ± 2
 Peak LVP (mmHg) 96 ± 12 94 ± 9 111 ± 11 114 ± 9
Loop areas
Septum Lateral wall Septum Lateral wall Anterior wall Anterior wall
Invasive method
 Loop area by LV pressure–strain(mmHg %) 693 ± 256 659 ± 264 155 ± 289* 1024 ± 486* 932 ± 239 322 ± 250*
Non-invasive method
 Loop area by estimated LVpressure–strain (mmHg %) 839 ± 230 770 ± 269 227 ± 278* 1031 ± 475* 914 ± 242 295 ± 221*

Values are mean ± SD. LBBB, left bundle branch block; EDP, end-diastolic pressure; anterior wall affected by ischaemia. Strain was measured by speckle tracking echocardiography.

*P < 0.05 vs. baseline.