The comparison of the resonant frequencies for the first pair of sensors, the ABAQUS, and the theory.

Mode Theory (Hz) FEM (Error %) PVDF (Error %) Strain Gauge (Error %)
1 58.84 59.2 (0.63) 58.01 (−1.4) 58.01 (−1.4)
2 368.8 370.8 (0.55) 367.3 (−0.4) 366.6 (−0.5)
3 1,032.8 1,038.2 (0.50) 1,028.3 (−0.4) 1,028.3 (−0.4)
4 2,023.8 2,033.5 (0.48) 2,028 (0.2) 2,026.6 (0.1)
5 3,345.2 3,361.1 (0.47) 3,352.3 (0.2) 3,355.3 (0.3)
6 Torsional 4,121.3 4,017(−2.5) 4,064.5(−1.3)
7 4,997.4 5,019.3 (0.44) 5,018 (0.4) 5,010 (0.2)
8 Torsional 6,868.8 6,714 (−2.2) 6,814 (−0.8)
9 6,979.6 7,007.2 (0.39) 7,007.3 (0.4) 7,018 (0.6)
10 9,292.3 9,321.5 (0.31) 9,297.3 (0.05) 9,295.3 (0.03)
11 Torsional 9,616.3 9,533 (−0.8) 9,631.3 (0.15)