The comparison of the resonant frequencies for the second pair of sensors, the ABAQUS, and the theory.

Mode Theory (Hz) FEM (Error %) PVDF (Error %) Strain Gauge (Error %)
1 58.84 59.2 (0.63) 56.52 (−2.5) 56.52 (−2.5)
2 368.8 3,70.8 (0.55) 361.1 (−2.0) 361.1 (−2.0)
3 1,032.8 1,038.2 (0.50) 1030 (−0.2)
4 2,023.8 2,033.5 (0.48) 2,010.3 (−0.6) 2,009 (−0.7)
5 3,345.2 3,361.1 (0.47) 3,336.3 (−0.2)
6 Torsional 4,121.3 4,017(−2.5) 4,045.5 (−1.8)
7 4,997.4 5,019.3 (0.44) 4,949.3 (−0.9) 4,949.6 (−0.9)
8 Torsional 6,868.8 6,714 (−2.2)
9 6,979.6 7,007.2 (0.39) 6,942 (−0.5)
10 9,292.3 9,321.5 (0.31) 9,205.3 (−0.9) 9,206.6 (−0.9)
11 Torsional 9,616.3 9,533 (−0.8)