Skip to main content
. 2011 Nov 16;107(5):1476–1488. doi: 10.1152/jn.00208.2011

Table 1.

Comparison intrinsic membrane properties for FS and RS cells

FS (n = 16) RS (n = 31)
Input resistance, MΩ* 163.92 ± 48.10 285.10 ± 80.61
Membrane time constant, ms* 11.83 ± 4.94 29.38 ± 10.32
Vrest, mV −67.88 ± 6.51 −67.15 ± 7.75
AP threshold, mV* −30.57 ± 6.24 −37.27 ± 7.54
Threshold I, nA* 0.16 ± 0.08 0.05 ± 0.03
Number of APs at threshold* 10.25 ± 10.72 3.65 ± 2.50
1st AP time, ms 266.13 ± 304.10 223.09 ± 237.20
AP half-width, ms* 0.46 ± 0.13 0.89 ± 0.20
Adaptation ratio* 0.78 ± 0.17 0.31 ± 0.09
Max firing rate, Hz* 199.00 ± 64.31 75.71 ± 15.53
FR vs. I slope, Hz/nA* 273.28 ± 81.56 109.90 ± 24.69

Values are means ± SD. FS, fast spiking; RS, regular spiking; Vrest, resting membrane potential; AP, action potential; I, current; FR, firing rate.

*

P < 0.01 by Student's t-test.