Fig 2.
Illustration of time point definitions. Time point tn (strained state) was defined as maximum LV pressure for beat 1 (tn1) and beat 2 (tn2). Time point t0 (reference state) was defined as last time frame before mitral leaflet separation (as represented by the rapid increase in plotted curve of distances (cm) between marker #33 and #4, see Fig 1) for beat 1 (t01) and beat 2 (t02).