Skip to main content
. Author manuscript; available in PMC: 2012 Apr 8.
Published in final edited form as: Crit Care Med. 2010 Apr;38(4):1141–1146. doi: 10.1097/CCM.0b013e3181ce1fe2

Figure 3.

Figure 3

Effects of 10% and 20% leaning on hemodynamic pressures during cardiopulmonary resuscitation adjusted for log of time. Values are mean ± sem. *Differs from no lean (reference line) by linear missed-effects regression model (p < .05). CPP, coronary perfusion pressure; RAD, right atrial diastolic pressure; AoS, aortic systolic pressure.