Case | Age Gender |
Aneurysm's morphology and location |
Treatment | End of Procedure Control |
Last Follow Up |
|
---|---|---|---|---|---|---|
11 | 62-year-old woman |
Wide-necked aneurysm proximal to the origin of the anterior communicating artery |
Neuroform stent + coil embolization after 1 month |
Stent patent, aneurysm excluded from the circulation |
After 8 months): unchanged |
|
12 | 57-year-old woman |
Left carotid siphon aneurysm partially vascularized after surgery |
Coil embolization end of procedure control: loop of one coil migrated into the siphon, recovery impossible treatment (after 1 month): placement of a Neuroform stent |
Stent patent, loop of the coil adhering to the arterial wal |
No further follow-up visits |
|
13 | 40-year-old woman |
Aneurysm of the left postero-inferior cerebellum |
Neuroform stent |
Stent patent, aneurysm partially recanalized |
After 8 months: unchanged |
|
14 | 53-year-old woman |
Aneurysm in the right carotid siphon embolized with coils on 16-11-2004, with neck revascularization |
Neuroform stent |
Stent patent | MR angiography after 5 days: unchanged No further follow-up visits: recent procedure |
|
15 | 55-year-old woman |
Aneurysm with undefined neck in the left carotid siphon |
Neuroform stent |
Stent patent | After 24 months: stent patent, aneurysm excluded from the circulation |
|
16 | 53-year-old woman |
Two wide-necked aneurysms in the right carotid siphon |
Neuroform stent |
Stent patent | After 5 months: stent patent, aneurysms excluded from the circulation |
|
17 | 49-year-old woman |
Small wide-necked aneurysm in the right carotid siphon |
Neuroform stent |
Stent patent | After 37 months: stent patent, aneurysm excluded from the circulation |
|
18 | 55-year-old woman |
Wide-necked aneurysm in the left carotid siphon |
INX stent |
Stent patent | After 29 months: stent patent, aneurysm excluded from the circulation |
|
19 | 44-year-old woman |
Dissecting basilar artery aneurysm |
Neuroform stent |
Stent patent | After 34 months: stent patent, aneurysm excluded from the circulation |
|
20 | 36-year-old woman |
Wide-necked aneurysm in the left carotid siphon |
Neuroform stent |
Stent patent | No further follow-up visits: recent procedure |