Table 7. CMV promoter detection in the presence of different naïve human gDNA samples.
Human gDNA | 5∶10* | 10∶10** | 20∶10*** | ||||||
Mean† CMV Ct | Mean ITCCMV Ct | P-Value | Mean† CMV Ct | Mean ITCCMV Ct | P-Value | Mean† CMV Ct | Mean ITCCMV Ct | P-Value | |
1 | 38.88 (0.35) | 36.27 (0.08) | <0.0001 | 36.77 (0.08) | 36.62 (0.12) | 0.3259 | 36.21 (0.09) | 36.65 (0.11) | 0.0172 |
2 | 38.37 (0.32) | 36.70 (0.12) | 0.0011 | 36.56 (0.14) | 36.97 (0.15) | 0.3333 | 36.11 (0.11) | 36.69 (0.08) | 0.0025 |
3 | 38.55 (0.42) | 36.82 (0.13) | 0.0045 | 36.78 (0.07) | 36.74 (0.13) | 0.7807 | 36.23 (0.14) | 36.91 (0.13) | 0.0081 |
4 | 38.83 (0.32) | 36.73 (0.18) | 0.0005 | 36.67 (0.12) | 36.67 (0.08) | 0.9355 | 36.06 (0.23) | 36.71 (0.04) | 0.0183 |
From five replicates of pSSV9-MD2-cmEPO plasmid DNA spiked into 500 ng naïve human gDNA. Standard error (in parenthesis).
5 copies of plasmid and 10 copies of ITC template.
10 copies of plasmid and 10 copies of ITC template.
20 copies of plasmid and 10 copies of ITC template.
The number of cycles of the real-time PCR program was set to 40.