Table 1. Calculated Effective concentrations EC50 for E2, EE2, E1 and Genistein in transgenic cyp19a1b-GFP zebrafish line based on measurement of either cyp19a1b or GFP gene expression by PCR and by image analysis.

Compound Method EC50 (nM) ±CI 95
E2 cyp19a1b mRNA 2.8 2,61−2,99
GFP mRNA 4.1 1.55−8.16
Image analysis 0.5 0.45−0.64
EE2 cyp19a1b mRNA 0.04 0.031−0.051
GFP mRNA 0.02 0.012−0.028
Image analysis 0.01 0.01−0.012
E1 cyp19a1b mRNA 2.3 2.14−1.81
GFP mRNA 1.3 0.88−2.15
Image analysis 2.4 2.04−2.5
Genistein cyp19a1b mRNA 3545 3052−3556
GFP mRNA 2466 1172−19261
Image analysis 2166 1872−2254

Results are expressed as mean ± confidence interval at 95% (CI 95).