Dimensions of all FIB cantilevers prepared: sample length l, sample height h and sample width b as measured using the Zeiss Supra 55VP scanning electron microscope system. Loaded cantilever length l* is also listed (for details please see figure 4).

sample length l (µm) height h (µm) width b (µm) loaded cantilever length l* (µm)
sample group 1: intra rod (level 1)
intra rod 1 15.75 4.84 4.15 13.43
intra rod 2 15.39 4.36 3.87 12.82
intra rod 3 16.17 5.28 4.86 14.18
sample group 2: multiple rods (level 2)
multiple rods 1 39.45 10.16 10.51 27.33
multiple rods 2 40.74 11.41 10.90 28.31
multiple rods 3 48.69 11.90 11.30 37.36
sample group 3: decussation (level 3)
decussation 1 37.25 9.23 9.23 26.78
decussation 2 38.82 14.11 12.67 27.85
decussation 3 45.02 13.23 12.50 28.16