Skip to main content
. 2012 Apr 10;53(1):53–63. doi: 10.1007/s10858-012-9623-8

Table 2.

Δχ-tensor parameters for lanthanide ions in complex with L3-FKBP12-rapamycin, L4-FKBP12-rapamycin, L3-GB1, L4-GB1, L4-Grb2 SH2 and L5-Grb2 SH2 determined on the basis of the crystal structure of the FKBP12-rapamycin complex (PDBID: 1fkb), GB1 (PDBID: 2rpv), Grb2 SH2 domains (PDBID: 1x0n) and the PCS values obtained from L3-FKBP12, L4-FKBP12, L3-GB1, L4-GB1, L4-Grb2 SH2 and L5-Grb2 SH2 signals

Δχaax Δχarh αb β b γb
L3-FKBP12 (Dy3+) 23.1 (±1.8) 20.2 (±1.2) 49 106 31
L3-FKBP12 (Tb3+) 34.0 (±2.5) 13.4 (±2.1) 53 106 17
L4-FKBP12 (Dy3+) 23.1 (±1.6) 19.0 (±0.7) 33 77 38
L4-FKBP12 (Tb3+) 29.2 (±1.2) 17.9 (±0.5) 35 69 9
L3-GB1 (Tm3+) −18.5 (±0.9) −18.0 (±0.4) 66 148 149
L3-GB1 (Tb3+) 39.2 (±1.0) 15.9 (±2.1) 97 145 158
L3-GB1 (Er3+) −9.4 (±0.7) −7.0 (±0.2) 71 138 136
L4-GB1 (Tm3+) −23.6 (±1.2) −20.0 (±0.7) 85 127 160
L4-GB1 (Tb3+) 41.8 (±2.3) 20.4 (±0.6) 94 125 153
L4-GB1 (Er3+) −9.3 (±0.8) −8.4 (±0.4) 74 115 145
L4-Grb2 SH2 (Dy3+)c 22.7 (±1.3) 17.6 (±0.7) 106 57 53
L4-Grb2 SH2 (Tb3+)c 29.2 (±1.7) 16.9 (±0.5) 97 52 34
L4-Grb2 SH2 (Tm3+)c −17.5 (±1.6) −17.1 (±0.5) 99 65 27
L5-Grb2 SH2 (Dy3+) 25.1 (±2.2) 21.0 (±1.2) 113 41 51
L5-Grb2 SH2 (Tb3+) 30.2 (±2.6) 21.1 (±1.0) 100 42 37
L5-Grb2 SH2 (Tm3+) −19.0 (±1.7) −19.1 (±1.0) 97 45 34

Δχ-tensor parameters were determined relative to the conformer 1 of the family of NMR structures of FKBP12-rapamycin complex (1fkb.pdb), GB1 (2rpv.pdb) and Grb2 SH2 (1x0n.pdb). Metal ion coordinates were x = 19.155 (±0.340), y = −17.082 (±0.199), z = 13.38 (±0.314) for L3-FKBP12, x = 15.782 (±0.258), y = −19.799 (±0.108), z = 10.386 (±0.263) for L4-FKBP12, x = −3.78 (±0.413), y = −2.12 (±0.548), z = −10.078 (±0.396) for L3-GB1, x = −1.036 (±0.224), y = −3.8 (±0.323), z = −12.954 (±0.219) for L4-GB1, x = −13.093 (±0.186), y = −5.491 (±0.404), z = −5.046 (±0.325) for L4-Grb2 SH2 and x = −13.270 (±0.304), y = −6.009 (±0.409), z = −5.562 (±0.515) for L5-Grb2 SH2. Deviation of the metal position was obtained by the Monte-Carlo protocol using 100 partial PCS data sets in which 30 % of the input data were randomly deleted

aΔχax and Δχrh values are in 10−32 [m3] and error estimates were obtained by the Monte-Carlo protocol using 100 partial PCS data sets in which 30 % of the input data were randomly deleted

bEuler angle rotations in ZYZ convention (degrees)

cSaio et al. (2011)