Skip to main content
. Author manuscript; available in PMC: 2013 May 1.
Published in final edited form as: Langmuir. 2012 Apr 16;28(17):6885–6892. doi: 10.1021/la300481e

Table 2.

Con A binding capacities of hydroxylated nylon membranes modified by different polyelectrolyte films.a

Polyelectrolyte films pH of PAH and/or PAA deposition solution Con A binding from breakthrough curve (mg/cm3) Con A binding from elution (mg/cm3)
PSS/PAH/PAA-NTA-Cu2+ 2 65±1 69±2
3 53±1 52±2
4 36±4 33±2
5 19±4 21±4
PAA-NTA-Cu2+ 2 60±1 59±2
3 52±2 52±6
4 37±4 37±5
5 12±2 11±3
PAA/PAH/PAA-NTA-Cu2+ 3 69±1 71±2
PAA/PEI/PAA-NTA-Cu2+ 3 73±4 71±7
a