Skip to main content
. 2012 Feb 8;7(1):e2. doi: 10.4081/hi.2012.e2

Table 1. Accuracy of stress testing for detecting obstructive coronary artery disease as defined by quantitative coronary angiography.

Test N Sensitivity Specificity
Exercise treadmill test 24,074 68 77
Exercise nuclear MPI 2,360 88 70
Vasodilator nuclear MPI 4,582 89 77
Dobutamine nuclear MPI 1,359 84 79
Exercise echocardiography 2,637 85 77
Dobutamine echocardiography 6,881 81 82

MPI, myocardial perfusion imaging.