Skip to main content
. 2012 May 22;39(6):3299–3318. doi: 10.1118/1.4718565

TABLE II.

The summary of parameter setting of HP-NCut.

Parameter Description Setting
R Defined in Eq. 17 12
r Defined in Eq. 23 8
σ Defined in Eq. 23 range from 0.03 to 0.1
K Number of the texton channels 16
r1 Radius of window used in boundary-detection function 2% of the image diagonal
τ Defined in Eq. 20 About one minus mean boundary energies over the image domain. Described in Sec. IV.E