Skip to main content
. Author manuscript; available in PMC: 2012 Jun 15.
Published in final edited form as: J Biomed Mater Res B Appl Biomater. 2011 Apr 18;98(1):80–88. doi: 10.1002/jbm.b.31834

FIGURE 1.

FIGURE 1

Mechanical properties of composites: (A) flexural strength, and (B) elastic modulus of NACP nanocomposites, microfill composite, hybrid composite, and RMGI. Each value is the mean of five measurements, with the error bar showing one standard deviation (mean ± sd; n = 5). The nanocomposite at 40% NACP had a strength that matched the commercial microfill composite (p > 0.1). [Color figure can be viewed in the online issue, which is available at wileyonlinelibrary.com.]