Skip to main content
. 2011 Oct 12;73(4):553–563. doi: 10.1111/j.1365-2125.2011.04116.x

Table 4.

Bias (MPE), precision (MAPE) (%) of different combinations of blood sampling time points used with the population model to estimate the CsA AUC, compared with the AUC calculated according to the trapezoidal method

Time points blood sampling (h) Bias (95% CI) (%) Precision (95% CI) (%)
0 (with model) 3.5 (−1.9, 8.8) 10.0 (7.0, 13.1)
2 4.4 (−6.5, 15.4) 20.2 (14.2, 26.3)
3 4.9 (−0.8, 10.6) 11.1 (7.7, 14.5)
5 −4.7 (−11.0, 1.7) 11.7 (7.7, 15.7)
8 5.1 (−0.8, 11.0) 10.8 (6.8, 14.8)
0, 2 1.7 (−2.3, 5.6) 6.5 (3.7, 9.2)
0, 3 2.2 (−2.0, 6.3) 7.7 (5.3, 10.0)
0, 5 −2.3 (−7.8, 3.1) 9.2 (5.6, 12.7)
0, 8 −10.6 (−16.5, −4.7) 14.6 (10.8, 18.3)
0, 1, 2 1.3 (−2.6, 5.2) 6.0 (3.2, 8.8)
0, 1, 3 −0.1 (−3.7, 3.6) 5.8 (3.4, 8.3)
0, 1.5, 3 1.6 (−1.2, 4.5) 4.6 (2.6, 6.7)
0, 2, 3 1.0 (−1.4, 3.4) 3.7 (2.1, 5.3)
0, 2, 5 4.1 (1.4, 6.8) 5.7 (3.8, 7.7)
0, 2, 8 1.7 (−0.9, 4.3) 4.4 (2.6, 6.2)
0, 3, 5 7.1 (4.2, 10.0) 8.0 (5.7, 10.3)
0; 3; 8 8.4 (4.7, 12.0) 9.1 (5.9, 12.3)
0, 1, 2, 3 4.6 (2.3, 6.8) 5.9 (4.4, 7.4)
0, 2, 3, 5 4.5 (1.9, 7.1) 5.9 (4.1, 7.8)
0, 2, 3, 8 2.8 (0.4, 5.1) 4.5 (2.8, 6.2)
0, 1, 2, 3, 5, 8, 12 −0.7 (−1.7, 0.3) 1.9 (1.2, 2.5)