Table 1.

The discrimination results of calibration and validation sets by different calibration models.

Parameters Method I Method II Method III Method IV Method V
PCs/LVs/Sw/Sv a 6 6 389 151 5
Calibration Set
Rb 0.9845 0.9539 0.9864 0.9844 0.9943
RMSECc 0.1433 0.2540 0.1351 0.1472 0.0878
Validation Set
Rb 0.9511 0.9256 0.9844 0.9950 0.9950
RMSEP c 0.2718 0.3194 0.1472 0.0829 0.0827
a

PCs/LVs/Sw/Sv: Principle components/latent variables/Selected wavelengths/Selected variables.

b

R: correlation coefficient.

c

RMSEC/RMSEP: root mean square error of calibration or prediction.