Skip to main content
. Author manuscript; available in PMC: 2012 Jun 18.
Published in final edited form as: Ear Hear. 2010 Aug;31(4):567–578. doi: 10.1097/AUD.0b013e3181da4d15

Table 1.

Mean and median stimulus levels associated with each category were used to determine within-subject reliability across two separate sessions. These comparisons were performed once with outliers included and again with outliers excluded. The reliability of the measurements was assessed using average stimulus-level differences, standard deviations of these differences, and correlations as shown.

Average Stimulus-level
Difference
Standard Deviation of
Difference
Correlation Coefficient
1 kHz 2 kHz 4 kHz 1 kHz 2 kHz 4 kHz 1 kHz 2 kHz 4 kHz
Mean without outliers 0.16 0.60 −0.61 7.6 6.6 7.8 0.95 0.95 0.94
Mean with outliers 0.17 0.64 −0.65 9.0 6.7 8.2 0.93 0.95 0.93
Median without outliers 0.18 0.81 −0.76 8.2 6.9 8.1 0.94 0.95 0.93
Median with outliers 0.24 0.86 −0.79 9.4 7.1 8.4 0.93 0.95 0.93