Skip to main content
. Author manuscript; available in PMC: 2012 Jun 18.
Published in final edited form as: Phys Med Biol. 2009 Aug 11;54(17):5271–5286. doi: 10.1088/0031-9155/54/17/013

Table 2.

Photon equivalent dose per MU to selected organs from the box treatment, the box treatment plus the 6-field boost and the 7-field IMRT treatment for prostate cancer. For the 4-field box plus the 6-field boost we assume that the two treatments use equal amounts of MUs. Accompanying each value is the percent relative error calculated for each value. The percent relative error is the variance of the calculated dose divided by the dose itself.

Photon equivalent dose (μSv MU−1)
Organ 4-field box (%) 4-field box + 6-field boost (%) 7-field IMRT (%)
Stomach 7.0 (1.6) 14.1 (1.1) 5.3 (2.9)
Colon 15.0 (1.3) 37.3 (0.9) 11.1 (3.2)
Liver 5.8 (1.2) 11.9 (0.9) 4.9 (2.0)
Lung 2.9 (1.1) 6.0 (1.0) 2.9 (2.0)
Esophagus 1.8 (5.6) 3.7 (3.9) 1.8 (3.2)
Pancreas 4.6 (3.7) 9.6 (2.5) 4.2 (3.5)
Brain 0.9 (3.3) 1.6 (2.4) 1.2 (3.6)
Active bone marrow 2.2 (1.3) 6.8 (0.6) 3.7 (4.3)
Small intestine 54.7 (0.5) 111.0 (0.3) 21.5 (0.8)
Spleen 5.0 (3.1) 10.6 (2.2) 4.3 (3.6)
Gall bladder 6.1 (2.9) 12.5 (2.1) 4.7 (2.5)
Heart 3.3 (1.7) 6.5 (1.3) 3.6 (3.6)
Lymph node 8.7 (4.2) 43.2 (1.2) 7.1 (1.6)
Kidneys 10.0 (1.7) 21.5 (1.2) 5.8 (3.7)
Thyroid 1.6 (10.0) 3.2 (7.1) 1.6 (10.8)