Table 1.

Measured fluorescence lifetimes and transfer efficiencies of the three experimental systems. The last column presents the corresponding calculated transfer efficiencies of the presented systems.

Sample R0(Å) τ(ns) Amplitude <τ>(ns) χ2 Measured transfer Calculated
Oligo-Donor 0.20 (0.171) 3.179 0.933
    1.38 (0.197)        
    3.45 (0.632)        
Donor-DL649 71.5 0.20 (0.180) 3.029 0.935 0.055 0.070
    1.35 (0.207)        
    3.31 (0.613)        
Donor plus 61.0 0.20 (0.184) 2.893 0.944 0.09 0.081
Avidin-DL750   1.33 (0.223)        
(A=8)   3.19 (0.593)        
Donor plus 71.5 0.20 (0.203) 2.793 0.928 0.12 0.123
Avidin-DL649   1.31 (0.245)        
(A=4.5)   3.13 (0.552)        
Donor-plus 71.5 0.20 (0.211) 2.724 0.925 0.143 0.156
Avidin-DL649   1.36 (0.257)        
(A=6)   3.08 (0.532)        

A: number of labeled acceptors. Calculation are based on a distance of 110 Å for DL649, a distance of closest approach of 105 Å for systems with avidin (100 Å DNA+donor), and a 55 -Å diameter of the labeled protein.