Skip to main content
. Author manuscript; available in PMC: 2013 Jun 19.
Published in final edited form as: Curr Biol. 2012 May 10;22(12):1047–1056. doi: 10.1016/j.cub.2012.04.012

Table 1. Simulation parameters.

The parameters of the simulation, organized by category, are listed along with their values as determined from minimizing the discrepancies between the experimental and simulation results. The uncertainties in the simulation parameters were estimated by varying the parameter and comparing the results with the experimental data, as described in experimental procedures.

PARAMETERS Values and Significance
Collagen fibril structure
1 Cleavage site spacing 67 nm (either 67 or 300 nm)
2 Stagger 0 nm (either 0 or 67 nm)
3 Hot spot spacing 1.2 µm, defines the peak in DPDs at ~1.3 µm
4 Hot spot spacing std. dev. 335 nm
5 Pre-cleaved sites 1.35%, determines downward curvature of MSD, only for active WT enzyme
6 adjacent track lateral spacing 3 nm (not varied)
Diffusion constants
7 1-D diffusion constant (D) 7.5 ± 1 µm2 s−1, intrinsic diffusion constant
8 Lateral jump rate (Pj) 0.5 s−1, rate of jumping to adjacent tracks
MMP1 binding properties
9 Binding to regular sites 150 s−1
10 Binding to hot spots 30000 s−1
11 Type I pause escape rate 5 s−1
12 Number of kinetic steps in type II (Gamma) pause 11 ± 3 steps
13 Rate of kinetic steps in type II pause 11 ± 3 s−1 (the average lifetime of the type II pauses is ~1 s)
14 Fraction of class II pauses at hot-spots 40 ± 15% (WT), 5 ± 5% (mutant), fraction of hot spot pauses that escape via gamma distribution
MMP1 cleavage properties
15 Percentage of cleavage after long dwells 5 ± 2%
16 Number of successive cuts after initial cut 15 ± 4, determines upward curvature of MSD and average motion after a long pause
17 Std. dev. of number of cuts 3, Reflects intrinsic variability in the number of successive cuts, which is a Gaussian distribution centered at 15 cuts with a standard deviation of 3.
Additional simulation parameters
18 Noise (σx) 170 nm, determines y-intercept of MSDs
19 Time step (Δt) 1 µs, simulation time step (not varied)