Inflammation degree produced by light curing units in different modes of lightening.

Day 7 Day 14 Day 30 Day 60
Inflammation degree Inflammation degree Inflammation degree Inflammation degree
LCU (mode of lightening) Gr. 0 Gr. I Gr. II Gr. III Gr. 0 Gr. I Gr. II Gr. III Gr. 0 Gr. I Gr. II Gr. III Gr. 0 Gr. I Gr. II Gr. III

QTH (full power) 1 3 1 0 0 1 4 0 1 4 0 0 1 2 2 0
LED (full power) 2 2 1 0 0 0 3 2 3 1 0 1 3 2 0 0
LED (ramp) 1 3 1 0 0 2 1 2 2 3 0 0 2 3 0 0
LED (pulse) 1 4 0 0 0 1 3 1 1 4 0 0 2 3 0 0
Control 4 1 0 0 1 4 0 0 4 1 0 0 3 1 0 0

Gr: Grade.